image

Thermal Shock Chamber

Thermal Shock Chamber Manufacturer in India

Thermal Shock Chamber Manufacturer in India

 

Product Specification and Technical parameter table

performance

Preheat room

Upper limit preheat temperature

200ºC

Heating time

+20~+200ºC ≈ 20min

Precool room

Lower limit precool temperature

-75ºC

Cooling time

+20 ~ -70ºC ≈ 80min

Workroom

Temperature shock range

(-55ºC ~ -10) ~ (50~ +150ºC)

Temperature fluctuation

≤±0.5ºC

Temperature deviation

≤±2ºC

Temperature revert time

≤5min

Temperature revert
conditions

CJ602S3Ⅰ

Test Condition 1

Test sample load: 10 kg with  plastic package IC; sample exposure: 30 min in +125ºC, 30 min in -40ºC

Test Condition 2

Test sample load: 10 kg with  plastic package IC; sample exposure :30 min in +150ºC, 5 min in ambient temp,30 min in -55ºC

CJ602S3Ⅱ

Test Condition 1

Test sample load: 20 kg with  plastic package IC; sample exposure: 30 min in +125ºC, 30 min in -40ºC

Test Condition 2

Test sample load: 20 kg with  plastic package IC; sample exposure :30 min in +150ºC, 5 min in ambient temp,30 min in -55ºC

Test Condition 3

Test sample load: 7.5 kg with  plastic package IC; sample exposure: 30 min in +150ºC, 30 min in -55ºC

CJ603S3Ⅰ

Test Condition 1

Test sample load: 10 kg with  plastic package IC; sample exposure: 30 min in +125ºC, 30 min in -40ºC

Test Condition 2

Test sample load: 10 kg with  plastic package IC; sample exposure :30 min in +150ºC, 5 min in ambient temp,30 min in -55ºC

CJ603S3Ⅱ

Test Condition 1

Test sample load: 20 kg with  plastic package IC; sample exposure: 30 min in +125ºC,30 min in -40ºC

Test Condition 2

Test sample load: 20 kg with  plastic package IC; sample exposure : 30 min in +150ºC, 5min in ambient temp,30 min in -55ºC

Test Condition 3

Test sample load: 10 kg with  plastic package IC; sample exposure: 30 min in +150ºC,30min in -55ºC

CJ605S3Ⅰ

Test Condition 1

Test sample load: 10 kg with  plastic package IC; sample exposure: 30 min in +125ºC,30min in -40ºC

Test Condition 2

Test sample load: 10 kg with  plastic package IC; sample exposure :30 min in +150ºC,5min in ambient temp,30 min in -55ºC

CJ605S3Ⅱ

Test Condition 1

Test sample load: 20 kg with  plastic package IC; sample exposure: 30 min in +125ºC,30min in -40ºC

Test Condition 2

Test sample load: 20 kg with  plastic package IC; sample exposure :30 min in +150ºC,5min in ambient temp,30 min in -55ºC

Test Condition 3

Test sample load: 10kg with  plastic package IC; sample exposure :30min in +150ºC,30min in -55ºC

construction

shell

cooling steel plate, surface spray

inner

steel plate

refrigeration

insulate

Rigid Polyurethane Foam + extra-fine glass-wool

mode

cascade refrigerating compressor

compressor

import compressor

Cable port(mm)

one on left side Φ50 mm

Controller

color LCD touchscreen display

recording equipment

temperature data recording(optional)

communication Interface

RS485 interface,RS232 interface

Power Supply

AC380V 50Hz Three-phase

Standard Configuration

A copy of the instruction and test report for the product, A certificate and quality assurance. 2 Shelf and 4 shelves.

Standards Applied

GJB150.5

 

 

Dimension Matrix

Model

 

TS – 80A

TS – 100A

TS – 150A

TS – 250A

TS – 560A

Workroom dimensions(mm)

D

400

400

500

60

80

W

500

500

600

70

100

H

400

500

500

60

70

Exterior dimensions(mm)

D

2500

2700

2900

3100

3300

W

1000

1000

1130

1190

 1220

H

1950

2000

2100

2290

2450

Installed power (KW)

35

48

50

60

75

46

56

56

70

85